NWPUEN=DISABLED, CMPMD=MODE0, INMUX=DIRECT, NMUX=CMPNN0, PMUX=CMPNP0, CMPHYP=DISABLED, RIEN=DISABLED, PWPUEN=DISABLED, FIEN=DISABLED, CMPHYN=DISABLED, INVEN=DISABLED
Input and Module Mode
| NMUX | Negative Input Select. 0 (CMPNN0): Select  1 (CMPNN1): Select  2 (CMPNN2): Select  3 (CMPNN3): Select  4 (CMPNN4): Select  5 (CMPNN5): Select  6 (CMPNN6): Select  7 (CMPNN7): Select  8 (CMPNN8): Select  9 (CMPNN9): Select  10 (CMPNN10): Select  11 (CMPNN11): Select  12 (CMPNN12): Select  13 (CMPNN13): Select  14 (CMPNN14): Select  15 (CMPNN15): Select  | 
| PMUX | Positive Input Select. 0 (CMPNP0): Select  1 (CMPNP1): Select  2 (CMPNP2): Select  3 (CMPNP3): Select  4 (CMPNP4): Select  5 (CMPNP5): Select  6 (CMPNP6): Select  7 (CMPNP7): Select  8 (CMPNP8): Select  9 (CMPNP9): Select  10 (CMPNP10): Select  11 (CMPNP11): Select  12 (CMPNP12): Select  13 (CMPNP13): Select  14 (CMPNP14): Select  15 (CMPNP15): Select  | 
| INMUX | Input MUX Select. 0 (DIRECT): Connects the NMUX signal to CP- and the PMUX signal to CP+. 1 (CMPP_VSS): Connects VSS to CP- and the PMUX signal to CP+. 2 (CMPP_DAC): Connects the NMUX signal to CP-, the PMUX signal to the Comparator DAC voltage reference, and the DAC output to CP+. 3 (CMPN_DAC): Connects the PMUX signal to CP+, the NMUX signal to the Comparator DAC voltage reference, and the DAC output to CP-. | 
| CMPMD | Comparator Mode. 0 (MODE0): Mode 0 (fastest response time, highest power consumption). 1 (MODE1): Mode 1. 2 (MODE2): Mode 2. 3 (MODE3): Mode 3 (slowest response time, lowest power consumption). | 
| FIEN | Falling Edge Interrupt Enable. 0 (DISABLED): Disable the comparator falling edge interrupt. 1 (ENABLED): Enable the comparator falling edge interrupt. | 
| RIEN | Rising Edge Interrupt Enable. 0 (DISABLED): Disable the comparator rising edge interrupt. 1 (ENABLED): Enable the comparator rising edge interrupt. | 
| DACLVL | Comparator DAC Output Level. | 
| NWPUEN | Negative Input Weak Pullup Enable. 0 (DISABLED): Disable the negative input weak pull up. 1 (ENABLED): Enable the negative input weak pull up. | 
| PWPUEN | Positive Input Weak Pullup Enable. 0 (DISABLED): Disable the positive input weak pull up. 1 (ENABLED): Enable the positive input weak pull up. | 
| CMPHYN | Negative Hysteresis Control. 0 (DISABLED): Disable negative hysteresis. 1 (NEG_5_MV): Set negative hysteresis to 5 mV. 2 (NEG_10_MV): Set negative hysteresis to 10 mV. 3 (NEG_20_MV): Set negative hysteresis to 20 mV. | 
| CMPHYP | Positive Hysteresis Control. 0 (DISABLED): Disable positive hysteresis. 1 (POS_5_MV): Set positive hysteresis to 5 mV. 2 (POS_10_MV): Set positive hysteresis to 10 mV. 3 (POS_20_MV): Set positive hysteresis to 20 mV. | 
| INVEN | Invert Comparator Output Enable. 0 (DISABLED): Do not invert the comparator output. 1 (ENABLED): Invert the comparator output. |